Apoch publishes this ladder for its ASL/ASPL series because it is the single most requested reference from OEM design teams, and because every sizing conversation starts with the same mistake: a controller chosen by port thread that cannot pass enough controlled-direction air to move the cylinder at speed.
The Ladder, Anchored on Catalogue Data
The industry-standard way to express a speed controller's capacity is effective area (the controlled-direction restriction, in mm²). Under choked-flow conditions at a 0.5 MPa supply, one mm² of effective area passes roughly 65 litres per minute (ANR) — a rule of thumb that tracks manufacturer catalogue data closely. Two published anchor points fix the ends of the ladder:
|
Port size |
Tube OD class |
Controlled-direction effective area |
Approx. flow at 0.5 MPa (ANR) |
Typical use |
|
M5 |
4–6 mm |
0.3 mm² (catalogue: AS1001F class) |
~20 ℓ/min |
Small cylinders, sensors, positioning |
|
1/8" |
6 mm |
0.5–1.0 mm² (typical catalogue class) |
~35–65 ℓ/min |
Compact actuators, grippers |
|
1/4" |
8 mm |
2–3 mm² (typical catalogue class) |
~130–200 ℓ/min |
General automation cylinders |
|
3/8" |
10–12 mm |
21 mm² (catalogue: AS4001F class) |
~1390 ℓ/min |
Large-bore, high-speed axes |
|
1/2" |
12–16 mm |
25+ mm² (largest common class) |
1600+ ℓ/min |
Presses, heavy slides |
Two things about this table decide whether a sourcing decision is correct or not:
First, the free-flow figure is not the controlled figure. A one-way speed controller passes air freely in one direction and meters in the other, and catalogues often quote the free direction because it is the larger, more flattering number. The restriction that controls your cylinder is the other figure — typically a fraction of it, because the needle and the check valve share one flow path. Anyone comparing quotes should compare controlled-direction effective area per tube size; comparing the free-flow column is how an undersized controller wins a bid. This asymmetry was covered in the markings guide as an ordering rule; here it is the reason the ladder itself must be read on the correct column.
Second, each tube-size step multiplies capacity, it does not add to it. From M5 to 3/8", flow capacity rises roughly 70-fold, which means the ladder is coarse: there is no "a bit more than 1/4"" option. If the cylinder's requirement falls between rungs, the correct move is the next rung up with attention to adjustment resolution — not a hopeful thread adaptation.
Matching the Controller to the Cylinder Bore
The requirement side of the ladder comes from simple physics: a piston of area A moving at speed v displaces air at A × v. Computed at a representative 300 mm/s stroke speed, this is the working form of the match speed controller size to cylinder bore chart — bore on the left, required flow in the middle, ladder rung on the right:
|
Cylinder bore |
Piston area |
Required flow at 300 mm/s |
With meter-out margin (2×) |
Ladder rung |
|
Ø25 |
4.9 cm² |
~88 ℓ/min |
~180 ℓ/min |
1/4" |
|
Ø40 |
12.6 cm² |
~226 ℓ/min |
~450 ℓ/min |
3/8" |
|
Ø63 |
31.2 cm² |
~560 ℓ/min |
~1120 ℓ/min |
3/8"–1/2" |
|
Ø80 |
50.3 cm² |
~905 ℓ/min |
~1810 ℓ/min |
1/2"+ |
|
Ø100 |
78.5 cm² |
~1415 ℓ/min |
~2830 ℓ/min |
beyond a single 1/2" |
The margin column is not padding — it is the usable adjustment window. A controller sized so that full-open exactly meets the speed target leaves the adjuster no travel: the smallest turn either does nothing or stalls the cylinder. Sizing one to two rungs up puts the working point in the middle of the needle's travel, where adjustment resolution is finest. The sizing formulas behind this table — and the trap between them — get their own treatment in the next article in this series; the chart here is the lookup layer.
This matching step is also where buyers most often ask the wrong question about pneumatic components generally: they ask "what fits the port?" when the circuit question is "what passes the flow?" Thread adapters are cheap and abundant; flow deficit is discovered on the commissioning floor, when the axis never reaches cycle time.
Answering the 6 mm Question Directly
The most common single-size query — how much flow does a 6mm speed controller pass — resolves through the ladder: a 6 mm OD (1/8" class) one-way controller typically shows a controlled-direction effective area of 0.5–1.0 mm², which under choked conditions at 0.5 MPa passes roughly 35–65 ℓ/min (ANR) in the metered direction, with the free direction passing several times that. In practical terms, that rung comfortably serves compact cylinders up to roughly Ø25–Ø32 at moderate speeds — grippers, small clamps, pick-and-place axes — and not much beyond. If the application needs more, the answer is a rung change, not a knob change.
One caution for multi-axis machines: the ladder is per-port. A machine with eight small axes does not have one flow budget; each axis sizes its own controller by its own bore and speed. If someone asked how much flow does a 6mm speed controller pass on behalf of an eight-axis machine, the correct answer starts with "which axis?" — the question is per-cylinder, not per-machine. This is why pneumatic equipment builders publish per-size flow figures rather than a single model-line capacity, and why a distributor who can produce the per-size table on request is usually the one who actually tests parts rather than relisting them.

Reading the Ladder as a Buyer
Three checks turn this chart into a procurement tool:
- Ask every shortlisted supplier for controlled-direction effective area per size. The numbers should differ between suppliers only within tolerance, not by an order of magnitude. A supplier whose "same size" passes twice the flow of everyone else is reporting the free direction — or has not measured.
- Match the rung to the bore chart before quoting thread. The match speed controller size to cylinder bore chart above takes two minutes and prevents the most expensive kind of sizing error, the kind found after installation.
- Treat the ladder as part of the supplier's core technologies evidence. Publishing per-size flow data requires flow-bench measurement on every size in the series — the kind of research and development infrastructure a factory owns and a trading desk rents by the email. Consistency of the ladder across a supplier's own series is as revealing as the numbers themselves.
The ladder also explains why experienced OEM engineers standardise on one series across a machine. One series means one adjuster behaviour, one needle feel and one flow curve per rung, across multiple industries and machine generations — a small but real gain in maintainability that catalogue shopping by thread size cannot deliver.
FAQ
Q: Is the ~65 ℓ/min per mm² rule accurate at other supply pressures? A: It holds under choked conditions around 0.5 MPa supply, where most cylinders operate. Below roughly 0.2 MPa the flow becomes subsonic and the linear rule breaks down — but cylinder speed control at such low pressures is rare, and catalogues quote figures at the standard condition for exactly this reason.
Q: My cylinder reaches full speed only near the end of the adjuster travel. Is it undersized? A: Almost certainly — the working point has fallen to the bottom of the ladder rung with no adjustment window. Move up one rung and re-test; you should land mid-travel. This is the classic symptom of sizing by thread instead of by the speed controller flow rate effective area chart by tube size logic.
Q: Can I parallel two small controllers to reach a bigger flow? A: Electrically it works; practically it doubles the adjustment points, doubles the leakage paths and makes future maintenance ambiguous. One correctly sized controller per port — one adjuster per axis — is the maintainable answer, and it matches how OEM assembly documentation is written.
Send Apoch — Apoch Pneumatic Technology Co., Ltd. — your cylinder bores, stroke speeds and tube sizes, and the engineering team returns the ASL/ASPL rung selection per axis with controlled-direction flow figures and samples for bench timing. The complete speed controller flow rate effective area chart by tube size for the ASL/ASPL range ships with every quotation, so your sizing review starts from measured data. Samples typically ship within 5 working days.
Phone:+86 15067778328
Mail:[email protected]
http://apochpneufittings.com/